Added: 11/08/2013

354 sqft of heating area

288 sqft room adjacent with 66 sqft powder room. HeatTech heating mats will be installed on top concrete subfloor, following with ceramic tile floor. Customer requested two thermostats for 240V power.
For 288 sqft room, combination of (3) heating mat systems was suggested. All three mats start by the thermostat location. One HTMAT-240-100 runs to the right and covers right part of the heating area, second HTMAT-240-100 runs down and covers bottom part of the area, HTMAT-240-60 will cover the rest of heating area between two HTMAT-240-100. The powder room will be covered with three rows of HTMAT-240-60.
Recommended materiel for the project: (2) HTMAT-240-100 and (2) HTMATKIT-240-60